Ultrasonic heat water flow sensors
Piezoelectric liquid flow sensors are often used in pairs and operate by utilizing the difference in transit time for a signal traveling in the direction of fluid flow compared to the transit time for a signal traveling against the fluid flow. This transit time difference is related to the velocity of the flow in the vessel, and therefore the flow or volume/second can be determined with the configuration of the vessel and the characteristics of the liquid.
Brand name: | JUDE |
Model No: | JDRC-14002 |
Material: | PZT-5 |
Material for flap: | Plastic material and Stainless metal |
MOQ: | Negotiable |
Supply capacity: | 10000 pair/month |
Packing: | 34×32×24mm/carton, about 5 kg/ctn |
Payment: | T/T, L/C |
Order Delivery Time: | Within 30 working days |
Transportation: | By air via express company, like DHL, TNT, UPS, EMS |
Models and Technical Data:
Type | Center Frequency | Sensitivity | Aftershock | Return ratio | Working temperature | Capacitance | Impedance |
JDRC-14001 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
JDRC-14002 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
JDRC-14003 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
Material for flap: Plastic material
Stainless metal
Electrical specification:
type | JDRC-14002 | Resonant impedance | <100Ω | Sensitivity | >35db |
capacitance | 1200PF±10% | Center frequency | 960KHz±10KHz | Return radio | >0.6mv |
Aftershock | <10Bus | Work temperature | 0°C-95°C | Sealing method | Epoxy resin potting |
Pressure resistance | >3.0MPa | Degree of protection | IP68 | Lead position | Sensor center |
Note:All materials comply with the requirements of environmental protection, while Piezoelectric ceramic exempt from lead restriction.
Package:
PCS/CTN | Packing plate (cm) | Packing box (cm) | Gross weight ( Kg ) | Net weight ( Kg ) |
500 | 32.5×30×3.5 | 34×32×26 | 6.3 | 5.6 |
Note:
1. Storage Condition:-25°C~11°C.
2. Please take Anti interference into consideration when designing driving circuit.
3. Driving voltage is suggested to be lower than 5Vpp.
4. Operating temperature:0°C~+95°C.
5. Maximum pressure endurance is 3.0MPa.
*All products can be customized according to customer requirements.
We specialize in piezoelectric ceramics and sensors for 20 years, with good quality and competitive price.
The company achieves the ISO9001 Certification.
Certification:
Factory:
Shipping:
Most our products delivery to customer by air via express company, like DHL,UPS,TNT ,EMS etc.
Transport time : one week can arrival customer office after send out from us .
We have enough foam inner packing and skin packing .
Contact:
E-mail: sales@pztceramics.com
Tel/Fax: 86-0536-2221236
Website: www.pztceramics.com
Ultrasonic heat water flow sensors
Piezoelectric liquid flow sensors are often used in pairs and operate by utilizing the difference in transit time for a signal traveling in the direction of fluid flow compared to the transit time for a signal traveling against the fluid flow. This transit time difference is related to the velocity of the flow in the vessel, and therefore the flow or volume/second can be determined with the configuration of the vessel and the characteristics of the liquid.
Brand name: | JUDE |
Model No: | JDRC-14002 |
Material: | PZT-5 |
Material for flap: | Plastic material and Stainless metal |
MOQ: | Negotiable |
Supply capacity: | 10000 pair/month |
Packing: | 34×32×24mm/carton, about 5 kg/ctn |
Payment: | T/T, L/C |
Order Delivery Time: | Within 30 working days |
Transportation: | By air via express company, like DHL, TNT, UPS, EMS |
Models and Technical Data:
Type | Center Frequency | Sensitivity | Aftershock | Return ratio | Working temperature | Capacitance | Impedance |
JDRC-14001 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
JDRC-14002 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
JDRC-14003 | 960±5KHz | >35dB | <10Bus | >0.6mv | 10℃-90℃ | 1200pf±10% | <100Ω |
Material for flap: Plastic material
Stainless metal
Electrical specification:
type | JDRC-14002 | Resonant impedance | <100Ω | Sensitivity | >35db |
capacitance | 1200PF±10% | Center frequency | 960KHz±10KHz | Return radio | >0.6mv |
Aftershock | <10Bus | Work temperature | 0°C-95°C | Sealing method | Epoxy resin potting |
Pressure resistance | >3.0MPa | Degree of protection | IP68 | Lead position | Sensor center |
Note:All materials comply with the requirements of environmental protection, while Piezoelectric ceramic exempt from lead restriction.
Package:
PCS/CTN | Packing plate (cm) | Packing box (cm) | Gross weight ( Kg ) | Net weight ( Kg ) |
500 | 32.5×30×3.5 | 34×32×26 | 6.3 | 5.6 |
Note:
1. Storage Condition:-25°C~11°C.
2. Please take Anti interference into consideration when designing driving circuit.
3. Driving voltage is suggested to be lower than 5Vpp.
4. Operating temperature:0°C~+95°C.
5. Maximum pressure endurance is 3.0MPa.
*All products can be customized according to customer requirements.
We specialize in piezoelectric ceramics and sensors for 20 years, with good quality and competitive price.
The company achieves the ISO9001 Certification.
Certification:
Factory:
Shipping:
Most our products delivery to customer by air via express company, like DHL,UPS,TNT ,EMS etc.
Transport time : one week can arrival customer office after send out from us .
We have enough foam inner packing and skin packing .
Contact:
E-mail: sales@pztceramics.com
Tel/Fax: 86-0536-2221236
Website: www.pztceramics.com